ACDCConverterDCTerminal
A DC electrical connection point at the AC/DC converter. The AC/DC converter is electrically connected also to the AC side. The AC connection is inherited from the AC conducting equipment in the same way as any other AC equipment. The AC/DC converter DC terminal is separate from generic DC terminal to restrict the connection with the AC side to AC/DC converter and so that no other DC conducting equipment can be connected to the AC side.
URI: cim:ACDCConverterDCTerminal
Type: Class
Inheritance
- IdentifiedObject
- ACDCTerminal
- DCBaseTerminal
- ACDCConverterDCTerminal
- DCBaseTerminal
- ACDCTerminal
Attributes
| Name | URI | Cardinality and Range | Inheritance | Description |
|---|---|---|---|---|
| DCConductingEquipment | cim:ACDCConverterDCTerminal.DCConductingEquipment | 1..1 ACDCConverter | direct | A DC converter terminal belong to an DC converter. |
| DCNode | cim:DCBaseTerminal.DCNode | 0..1 DCNode | DCBaseTerminal | The DC connectivity node to which this DC base terminal connects with zero impedance. |
| sequenceNumber | cim:ACDCTerminal.sequenceNumber | 1..1 integer | ACDCTerminal | The orientation of the terminal connections for a multiple terminal conducting equipment. The sequence numbering starts with 1 and additional terminals should follow in increasing order. The first terminal is the starting point for a two terminal branch. |
| BusNameMarker | cim:ACDCTerminal.BusNameMarker | 0..1 BusNameMarker | ACDCTerminal | The bus name marker used to name the bus (topological node). |
| mRID | cim:IdentifiedObject.mRID | 1..1 string | IdentifiedObject | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
| description | cim:IdentifiedObject.description | 0..1 string | IdentifiedObject | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
| energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string | IdentifiedObject | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. |
| name | cim:IdentifiedObject.name | 1..1 string | IdentifiedObject | The name is any free human readable and possibly non unique text naming the object. |
| shortName | eu:IdentifiedObject.shortName | 0..1 string | IdentifiedObject | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. |
Format Examples
{
"@context": {"rdf": "http://www.w3.org/1999/02/22-rdf-syntax-ns#", "linkml": "https://w3id.org/linkml/", "sh": "http://www.w3.org/ns/shacl#", "skos": "http://www.w3.org/2004/02/skos/core#", "dc": "http://purl.org/dc/elements/1.1/", "profcim": "http://iec.ch/TC57/ns/CIM/prof-cim#", "owl": "http://www.w3.org/2002/07/owl#", "cim": "http://iec.ch/TC57/CIM100#", "this": "http://ucaiug.org/ns/CGMES/CoreEquipment-EU/3.0#", "cims": "http://iec.ch/TC57/1999/rdf-schema-extensions-19990926#", "dct": "http://purl.org/dc/terms/", "rdfs": "http://www.w3.org/2000/01/rdf-schema#", "dcat": "http://www.w3.org/ns/dcat#", "eu": "http://iec.ch/TC57/CIM100-European#"},
"@id": "urn:uuid:<uuid>",
"@type": "cim:ACDCConverterDCTerminal",
"cim:ACDCConverterDCTerminal.DCConductingEquipment": { "@id": "urn:uuid:<uuid of ACDCConverter>" },
"cim:DCBaseTerminal.DCNode": { "@id": "urn:uuid:<uuid of DCNode>" },
"cim:ACDCTerminal.sequenceNumber": "integer",
"cim:ACDCTerminal.BusNameMarker": { "@id": "urn:uuid:<uuid of BusNameMarker>" },
"cim:IdentifiedObject.mRID": "string",
"cim:IdentifiedObject.description": "string",
"eu:IdentifiedObject.energyIdentCodeEic": "string",
"cim:IdentifiedObject.name": "string",
"eu:IdentifiedObject.shortName": "string"
}
<cim:ACDCConverterDCTerminal rdf:ID="_<uuid>">
<cim:ACDCConverterDCTerminal.DCConductingEquipment rdf:resource="#_<uuid of ACDCConverter>" />
<cim:DCBaseTerminal.DCNode rdf:resource="#_<uuid of DCNode>" />
<cim:ACDCTerminal.sequenceNumber>integer</cim:ACDCTerminal.sequenceNumber>
<cim:ACDCTerminal.BusNameMarker rdf:resource="#_<uuid of BusNameMarker>" />
<cim:IdentifiedObject.mRID>string</cim:IdentifiedObject.mRID>
<cim:IdentifiedObject.description>string</cim:IdentifiedObject.description>
<eu:IdentifiedObject.energyIdentCodeEic>string</eu:IdentifiedObject.energyIdentCodeEic>
<cim:IdentifiedObject.name>string</cim:IdentifiedObject.name>
<eu:IdentifiedObject.shortName>string</eu:IdentifiedObject.shortName>
</cim:ACDCConverterDCTerminal>
{
"DCConductingEquipment": "<ACDCConverter>",
"DCNode": "<DCNode>",
"sequenceNumber": "integer",
"BusNameMarker": "<BusNameMarker>",
"mRID": "string",
"description": "string",
"energyIdentCodeEic": "string",
"name": "string",
"shortName": "string"
}
<urn:uuid:<graph-id>> {
<urn:uuid:<uuid>>
a cim:ACDCConverterDCTerminal ;
cim:ACDCConverterDCTerminal.DCConductingEquipment <urn:uuid:<uuid of ACDCConverter>> ;
cim:DCBaseTerminal.DCNode <urn:uuid:<uuid of DCNode>> ;
cim:ACDCTerminal.sequenceNumber "integer" ;
cim:ACDCTerminal.BusNameMarker <urn:uuid:<uuid of BusNameMarker>> ;
cim:IdentifiedObject.mRID "string" ;
cim:IdentifiedObject.description "string" ;
eu:IdentifiedObject.energyIdentCodeEic "string" ;
cim:IdentifiedObject.name "string" ;
eu:IdentifiedObject.shortName "string" .
}
Schema Source
- from schema: http://ucaiug.org/ns/CGMES/CoreEquipment-EU/3.0