VoltageLimit
Operational limit applied to voltage.The use of operational VoltageLimit is preferred instead of limits defined at VoltageLevel. The operational VoltageLimits are used, if present.
URI: cim:VoltageLimit
Type: Class
Inheritance
- IdentifiedObject
- OperationalLimit
- VoltageLimit
- OperationalLimit
Attributes
| Name | URI | Cardinality and Range | Inheritance | Description |
|---|---|---|---|---|
| normalValue | cim:VoltageLimit.normalValue | 1..1 Voltage | direct | The normal limit on voltage. High or low limit nature of the limit depends upon the properties of the operational limit type. The attribute shall be a positive value or zero. |
| OperationalLimitSet | cim:OperationalLimit.OperationalLimitSet | 1..1 OperationalLimitSet | OperationalLimit | The limit set to which the limit values belong. |
| OperationalLimitType | cim:OperationalLimit.OperationalLimitType | 1..1 OperationalLimitType | OperationalLimit | The limit type associated with this limit. |
| mRID | cim:IdentifiedObject.mRID | 1..1 string | IdentifiedObject | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
| description | cim:IdentifiedObject.description | 0..1 string | IdentifiedObject | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
| energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string | IdentifiedObject | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. |
| name | cim:IdentifiedObject.name | 1..1 string | IdentifiedObject | The name is any free human readable and possibly non unique text naming the object. |
| shortName | eu:IdentifiedObject.shortName | 0..1 string | IdentifiedObject | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. |
Format Examples
{
"@context": {"rdf": "http://www.w3.org/1999/02/22-rdf-syntax-ns#", "linkml": "https://w3id.org/linkml/", "sh": "http://www.w3.org/ns/shacl#", "skos": "http://www.w3.org/2004/02/skos/core#", "dc": "http://purl.org/dc/elements/1.1/", "profcim": "http://iec.ch/TC57/ns/CIM/prof-cim#", "owl": "http://www.w3.org/2002/07/owl#", "cim": "http://iec.ch/TC57/CIM100#", "this": "http://ucaiug.org/ns/CGMES/CoreEquipment-EU/3.0#", "cims": "http://iec.ch/TC57/1999/rdf-schema-extensions-19990926#", "dct": "http://purl.org/dc/terms/", "rdfs": "http://www.w3.org/2000/01/rdf-schema#", "dcat": "http://www.w3.org/ns/dcat#", "eu": "http://iec.ch/TC57/CIM100-European#"},
"@id": "urn:uuid:<uuid>",
"@type": "cim:VoltageLimit",
"cim:VoltageLimit.normalValue": "float",
"cim:OperationalLimit.OperationalLimitSet": { "@id": "urn:uuid:<uuid of OperationalLimitSet>" },
"cim:OperationalLimit.OperationalLimitType": { "@id": "urn:uuid:<uuid of OperationalLimitType>" },
"cim:IdentifiedObject.mRID": "string",
"cim:IdentifiedObject.description": "string",
"eu:IdentifiedObject.energyIdentCodeEic": "string",
"cim:IdentifiedObject.name": "string",
"eu:IdentifiedObject.shortName": "string"
}
<cim:VoltageLimit rdf:ID="_<uuid>">
<cim:VoltageLimit.normalValue>float</cim:VoltageLimit.normalValue>
<cim:OperationalLimit.OperationalLimitSet rdf:resource="#_<uuid of OperationalLimitSet>" />
<cim:OperationalLimit.OperationalLimitType rdf:resource="#_<uuid of OperationalLimitType>" />
<cim:IdentifiedObject.mRID>string</cim:IdentifiedObject.mRID>
<cim:IdentifiedObject.description>string</cim:IdentifiedObject.description>
<eu:IdentifiedObject.energyIdentCodeEic>string</eu:IdentifiedObject.energyIdentCodeEic>
<cim:IdentifiedObject.name>string</cim:IdentifiedObject.name>
<eu:IdentifiedObject.shortName>string</eu:IdentifiedObject.shortName>
</cim:VoltageLimit>
{
"normalValue": "float",
"OperationalLimitSet": "<OperationalLimitSet>",
"OperationalLimitType": "<OperationalLimitType>",
"mRID": "string",
"description": "string",
"energyIdentCodeEic": "string",
"name": "string",
"shortName": "string"
}
<urn:uuid:<graph-id>> {
<urn:uuid:<uuid>>
a cim:VoltageLimit ;
cim:VoltageLimit.normalValue "float" ;
cim:OperationalLimit.OperationalLimitSet <urn:uuid:<uuid of OperationalLimitSet>> ;
cim:OperationalLimit.OperationalLimitType <urn:uuid:<uuid of OperationalLimitType>> ;
cim:IdentifiedObject.mRID "string" ;
cim:IdentifiedObject.description "string" ;
eu:IdentifiedObject.energyIdentCodeEic "string" ;
cim:IdentifiedObject.name "string" ;
eu:IdentifiedObject.shortName "string" .
}
Schema Source
- from schema: http://ucaiug.org/ns/CGMES/CoreEquipment-EU/3.0