NonConformLoad
NonConformLoad represents loads that do not follow a daily load change pattern and whose changes are not correlated with the daily load change pattern.
URI: cim:NonConformLoad
Type: Class
%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
class NonConformLoad
click NonConformLoad href "/Models/Profiles/CoreEquipment/ConcreteClasses/NonConformLoad/"
style NonConformLoad fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConsumer <|-- NonConformLoad : inherits
click EnergyConsumer href "/Models/Profiles/CoreEquipment/AbstractClasses/EnergyConsumer/"
style EnergyConsumer fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConnection <|-- EnergyConsumer : inherits
click EnergyConnection href "/Models/Profiles/CoreEquipment/AbstractClasses/EnergyConnection/"
style EnergyConnection fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment <|-- EnergyConnection : inherits
click ConductingEquipment href "/Models/Profiles/CoreEquipment/AbstractClasses/ConductingEquipment/"
style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment <|-- ConductingEquipment : inherits
click Equipment href "/Models/Profiles/CoreEquipment/AbstractClasses/Equipment/"
style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
PowerSystemResource <|-- Equipment : inherits
click PowerSystemResource href "/Models/Profiles/CoreEquipment/AbstractClasses/PowerSystemResource/"
style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
IdentifiedObject <|-- PowerSystemResource : inherits
click IdentifiedObject href "/Models/Profiles/CoreEquipment/AbstractClasses/IdentifiedObject/"
style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
NonConformLoad --> NonConformLoadGroup : NonConformLoad.LoadGroup
NonConformLoadGroup
click NonConformLoadGroup href "/Models/Profiles/CoreEquipment/ConcreteClasses/NonConformLoadGroup/"
style NonConformLoadGroup fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EnergyConsumer --> LoadResponseCharacteristic : EnergyConsumer.LoadResponse
LoadResponseCharacteristic
click LoadResponseCharacteristic href "/Models/Profiles/CoreEquipment/ConcreteClasses/LoadResponseCharacteristic/"
style LoadResponseCharacteristic fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment --> BaseVoltage : ConductingEquipment.BaseVoltage
BaseVoltage
click BaseVoltage href "/Models/Profiles/CoreEquipment/ConcreteClasses/BaseVoltage/"
style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
ConductingEquipment --> Terminal : ConductingEquipment.Terminals
Terminal
click Terminal href "/Models/Profiles/CoreEquipment/ConcreteClasses/Terminal/"
style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> EquipmentContainer : Equipment.EquipmentContainer
EquipmentContainer
click EquipmentContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Equipment --> OperationalLimitSet : Equipment.OperationalLimitSet
OperationalLimitSet
click OperationalLimitSet href "/Models/Profiles/CoreEquipment/ConcreteClasses/OperationalLimitSet/"
style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
BaseVoltage --> ConductingEquipment : BaseVoltage.ConductingEquipment
BaseVoltage
click BaseVoltage href "/Models/Profiles/CoreEquipment/ConcreteClasses/BaseVoltage/"
style BaseVoltage fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
EquipmentContainer --> Equipment : EquipmentContainer.Equipments
EquipmentContainer
click EquipmentContainer href "/Models/Profiles/CoreEquipment/AbstractClasses/EquipmentContainer/"
style EquipmentContainer fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
LoadResponseCharacteristic --> EnergyConsumer : LoadResponseCharacteristic.EnergyConsumer
LoadResponseCharacteristic
click LoadResponseCharacteristic href "/Models/Profiles/CoreEquipment/ConcreteClasses/LoadResponseCharacteristic/"
style LoadResponseCharacteristic fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
NonConformLoadGroup --> NonConformLoad : NonConformLoadGroup.EnergyConsumers
NonConformLoadGroup
click NonConformLoadGroup href "/Models/Profiles/CoreEquipment/ConcreteClasses/NonConformLoadGroup/"
style NonConformLoadGroup fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
OperationalLimitSet --> Equipment : OperationalLimitSet.Equipment
OperationalLimitSet
click OperationalLimitSet href "/Models/Profiles/CoreEquipment/ConcreteClasses/OperationalLimitSet/"
style OperationalLimitSet fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
Terminal --> ConductingEquipment : Terminal.ConductingEquipment
Terminal
click Terminal href "/Models/Profiles/CoreEquipment/ConcreteClasses/Terminal/"
style Terminal fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
NonConformLoad : NonConformLoad.LoadGroup
EnergyConsumer : EnergyConsumer.pfixed
EnergyConsumer : EnergyConsumer.pfixedPct
EnergyConsumer : EnergyConsumer.qfixed
EnergyConsumer : EnergyConsumer.qfixedPct
EnergyConsumer : EnergyConsumer.LoadResponse
ConductingEquipment : ConductingEquipment.BaseVoltage
ConductingEquipment : ConductingEquipment.Terminals
Equipment : Equipment.aggregate
Equipment : Equipment.normallyInService
Equipment : Equipment.EquipmentContainer
Equipment : Equipment.OperationalLimitSet
IdentifiedObject : IdentifiedObject.description
IdentifiedObject : IdentifiedObject.energyIdentCodeEic
IdentifiedObject : IdentifiedObject.mRID
IdentifiedObject : IdentifiedObject.name
IdentifiedObject : IdentifiedObject.shortName
Inheritance
Attributes
| Name | URI | Cardinality and Range | Description | Inheritance |
|---|---|---|---|---|
| LoadGroup | cim:NonConformLoad.LoadGroup | No cardinality available NonConformLoadGroup | Group of this ConformLoad. | direct |
| pfixed | cim:EnergyConsumer.pfixed | No cardinality available ActivePower | Active power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
| pfixedPct | cim:EnergyConsumer.pfixedPct | No cardinality available PerCent | Fixed active power as a percentage of load group fixed active power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
| qfixed | cim:EnergyConsumer.qfixed | No cardinality available ReactivePower | Reactive power of the load that is a fixed quantity and does not vary as load group value varies. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
| qfixedPct | cim:EnergyConsumer.qfixedPct | No cardinality available PerCent | Fixed reactive power as a percentage of load group fixed reactive power. Used to represent the time-varying components. Load sign convention is used, i.e. positive sign means flow out from a node. | EnergyConsumer |
| LoadResponse | cim:EnergyConsumer.LoadResponse | No cardinality available LoadResponseCharacteristic | The load response characteristic of this load. If missing, this load is assumed to be constant power. | EnergyConsumer |
| BaseVoltage | cim:ConductingEquipment.BaseVoltage | No cardinality available BaseVoltage | Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers. | ConductingEquipment |
| Terminals | cim:ConductingEquipment.Terminals | No cardinality available Terminal | Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes. | ConductingEquipment |
| aggregate | cim:Equipment.aggregate | No cardinality available boolean | The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. | |
| The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection. | Equipment | |||
| normallyInService | cim:Equipment.normallyInService | No cardinality available boolean | Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model. | Equipment |
| EquipmentContainer | cim:Equipment.EquipmentContainer | No cardinality available EquipmentContainer | Container of this equipment. | Equipment |
| OperationalLimitSet | cim:Equipment.OperationalLimitSet | No cardinality available OperationalLimitSet | The operational limit sets associated with this equipment. | Equipment |
| description | cim:IdentifiedObject.description | No cardinality available string | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. | IdentifiedObject |
| energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | No cardinality available string | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. | IdentifiedObject |
| mRID | cim:IdentifiedObject.mRID | No cardinality available string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. | |
| For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject | |||
| name | cim:IdentifiedObject.name | No cardinality available string | The name is any free human readable and possibly non unique text naming the object. | IdentifiedObject |
| shortName | eu:IdentifiedObject.shortName | No cardinality available string | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. | IdentifiedObject |