Skip to content

DCTerminal

An electrical connection point to generic DC conducting equipment.

URI: cim:DCTerminal
Type: Class

DCTerminal class diagram

Inheritance

Attributes

Name URI Cardinality and Range Inheritance Description
DCConductingEquipment cim:DCTerminal.DCConductingEquipment 1..1 DCConductingEquipment direct An DC terminal belong to a DC conducting equipment.
DCNode cim:DCBaseTerminal.DCNode 0..1 DCNode DCBaseTerminal The DC connectivity node to which this DC base terminal connects with zero impedance.
sequenceNumber cim:ACDCTerminal.sequenceNumber 1..1 integer ACDCTerminal The orientation of the terminal connections for a multiple terminal conducting equipment. The sequence numbering starts with 1 and additional terminals should follow in increasing order. The first terminal is the starting point for a two terminal branch.
BusNameMarker cim:ACDCTerminal.BusNameMarker 0..1 BusNameMarker ACDCTerminal The bus name marker used to name the bus (topological node).
mRID cim:IdentifiedObject.mRID 1..1 string IdentifiedObject Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
description cim:IdentifiedObject.description 0..1 string IdentifiedObject The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
energyIdentCodeEic eu:IdentifiedObject.energyIdentCodeEic 0..1 string IdentifiedObject The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site.
name cim:IdentifiedObject.name 1..1 string IdentifiedObject The name is any free human readable and possibly non unique text naming the object.
shortName eu:IdentifiedObject.shortName 0..1 string IdentifiedObject The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum.

Format Examples

{
    "@context": {"rdf": "http://www.w3.org/1999/02/22-rdf-syntax-ns#", "linkml": "https://w3id.org/linkml/", "sh": "http://www.w3.org/ns/shacl#", "skos": "http://www.w3.org/2004/02/skos/core#", "dc": "http://purl.org/dc/elements/1.1/", "profcim": "http://iec.ch/TC57/ns/CIM/prof-cim#", "owl": "http://www.w3.org/2002/07/owl#", "cim": "http://iec.ch/TC57/CIM100#", "this": "http://ucaiug.org/ns/CGMES/CoreEquipment-EU/3.0#", "cims": "http://iec.ch/TC57/1999/rdf-schema-extensions-19990926#", "dct": "http://purl.org/dc/terms/", "rdfs": "http://www.w3.org/2000/01/rdf-schema#", "dcat": "http://www.w3.org/ns/dcat#", "eu": "http://iec.ch/TC57/CIM100-European#"},
    "@id": "urn:uuid:<uuid>",
    "@type": "cim:DCTerminal",
    "cim:DCTerminal.DCConductingEquipment": { "@id": "urn:uuid:<uuid of DCConductingEquipment>" },
    "cim:DCBaseTerminal.DCNode": { "@id": "urn:uuid:<uuid of DCNode>" },
    "cim:ACDCTerminal.sequenceNumber": "integer",
    "cim:ACDCTerminal.BusNameMarker": { "@id": "urn:uuid:<uuid of BusNameMarker>" },
    "cim:IdentifiedObject.mRID": "string",
    "cim:IdentifiedObject.description": "string",
    "eu:IdentifiedObject.energyIdentCodeEic": "string",
    "cim:IdentifiedObject.name": "string",
    "eu:IdentifiedObject.shortName": "string"
}
<cim:DCTerminal rdf:ID="_<uuid>">
    <cim:DCTerminal.DCConductingEquipment rdf:resource="#_<uuid of DCConductingEquipment>" />
    <cim:DCBaseTerminal.DCNode rdf:resource="#_<uuid of DCNode>" />
    <cim:ACDCTerminal.sequenceNumber>integer</cim:ACDCTerminal.sequenceNumber>
    <cim:ACDCTerminal.BusNameMarker rdf:resource="#_<uuid of BusNameMarker>" />
    <cim:IdentifiedObject.mRID>string</cim:IdentifiedObject.mRID>
    <cim:IdentifiedObject.description>string</cim:IdentifiedObject.description>
    <eu:IdentifiedObject.energyIdentCodeEic>string</eu:IdentifiedObject.energyIdentCodeEic>
    <cim:IdentifiedObject.name>string</cim:IdentifiedObject.name>
    <eu:IdentifiedObject.shortName>string</eu:IdentifiedObject.shortName>
</cim:DCTerminal>
{
    "DCConductingEquipment": "<DCConductingEquipment>",
    "DCNode": "<DCNode>",
    "sequenceNumber": "integer",
    "BusNameMarker": "<BusNameMarker>",
    "mRID": "string",
    "description": "string",
    "energyIdentCodeEic": "string",
    "name": "string",
    "shortName": "string"
}
<urn:uuid:<graph-id>> {
    <urn:uuid:<uuid>>
        a cim:DCTerminal ;
        cim:DCTerminal.DCConductingEquipment <urn:uuid:<uuid of DCConductingEquipment>> ;
        cim:DCBaseTerminal.DCNode <urn:uuid:<uuid of DCNode>> ;
        cim:ACDCTerminal.sequenceNumber "integer" ;
        cim:ACDCTerminal.BusNameMarker <urn:uuid:<uuid of BusNameMarker>> ;
        cim:IdentifiedObject.mRID "string" ;
        cim:IdentifiedObject.description "string" ;
        eu:IdentifiedObject.energyIdentCodeEic "string" ;
        cim:IdentifiedObject.name "string" ;
        eu:IdentifiedObject.shortName "string" .
}

Schema Source