Skip to content

ReactiveCapabilityCurve

Reactive power rating envelope versus the synchronous machine's active power, in both the generating and motoring modes. For each active power value there is a corresponding high and low reactive power limit value. Typically there will be a separate curve for each coolant condition, such as hydrogen pressure. The Y1 axis values represent reactive minimum and the Y2 axis values represent reactive maximum.

URI: cim:ReactiveCapabilityCurve
Type: Class

%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
    class ReactiveCapabilityCurve
    click ReactiveCapabilityCurve href "/Models/Profiles/CoreEquipment/ConcreteClasses/ReactiveCapabilityCurve/"
    style ReactiveCapabilityCurve fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Curve <|-- ReactiveCapabilityCurve : inherits
            click Curve href "/Models/Profiles/CoreEquipment/AbstractClasses/Curve/"
            style Curve fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        IdentifiedObject <|-- Curve : inherits
            click IdentifiedObject href "/Models/Profiles/CoreEquipment/AbstractClasses/IdentifiedObject/"
            style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ReactiveCapabilityCurve --> EquivalentInjection : ReactiveCapabilityCurve.EquivalentInjection

        EquivalentInjection
            click EquivalentInjection href "/Models/Profiles/CoreEquipment/ConcreteClasses/EquivalentInjection/"
            style EquivalentInjection fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        ReactiveCapabilityCurve --> SynchronousMachine : ReactiveCapabilityCurve.InitiallyUsedBySynchronousMachines

        SynchronousMachine
            click SynchronousMachine href "/Models/Profiles/CoreEquipment/ConcreteClasses/SynchronousMachine/"
            style SynchronousMachine fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Curve --> CurveData : Curve.CurveDatas

        CurveData
            click CurveData href "/Models/Profiles/CoreEquipment/ConcreteClasses/CurveData/"
            style CurveData fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        CurveData --> Curve : CurveData.Curve

        CurveData
            click CurveData href "/Models/Profiles/CoreEquipment/ConcreteClasses/CurveData/"
            style CurveData fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        EquivalentInjection --> ReactiveCapabilityCurve : EquivalentInjection.ReactiveCapabilityCurve

        EquivalentInjection
            click EquivalentInjection href "/Models/Profiles/CoreEquipment/ConcreteClasses/EquivalentInjection/"
            style EquivalentInjection fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        SynchronousMachine --> ReactiveCapabilityCurve : SynchronousMachine.InitialReactiveCapabilityCurve

        SynchronousMachine
            click SynchronousMachine href "/Models/Profiles/CoreEquipment/ConcreteClasses/SynchronousMachine/"
            style SynchronousMachine fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Curve --> CurveStyle : Curve.curveStyle

        CurveStyle
            click CurveStyle href "/Models/Profiles/CoreEquipment/Enumerations/CurveStyle/"
            style CurveStyle fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Curve --> UnitSymbol : Curve.xUnit

        UnitSymbol
            click UnitSymbol href "/Models/Profiles/CoreEquipment/Enumerations/UnitSymbol/"
            style UnitSymbol fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Curve --> UnitSymbol : Curve.y1Unit

        UnitSymbol
            click UnitSymbol href "/Models/Profiles/CoreEquipment/Enumerations/UnitSymbol/"
            style UnitSymbol fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white
        Curve --> UnitSymbol : Curve.y2Unit

        UnitSymbol
            click UnitSymbol href "/Models/Profiles/CoreEquipment/Enumerations/UnitSymbol/"
            style UnitSymbol fill:#4D2D18,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ReactiveCapabilityCurve : ReactiveCapabilityCurve.EquivalentInjection
        ReactiveCapabilityCurve : ReactiveCapabilityCurve.InitiallyUsedBySynchronousMachines
        Curve : Curve.curveStyle
        Curve : Curve.xUnit
        Curve : Curve.y1Unit
        Curve : Curve.y2Unit
        Curve : Curve.CurveDatas
        IdentifiedObject : IdentifiedObject.description
        IdentifiedObject : IdentifiedObject.energyIdentCodeEic
        IdentifiedObject : IdentifiedObject.mRID
        IdentifiedObject : IdentifiedObject.name
        IdentifiedObject : IdentifiedObject.shortName

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
EquivalentInjection cim:ReactiveCapabilityCurve.EquivalentInjection No cardinality available EquivalentInjection The equivalent injection using this reactive capability curve. direct
InitiallyUsedBySynchronousMachines cim:ReactiveCapabilityCurve.InitiallyUsedBySynchronousMachines No cardinality available SynchronousMachine Synchronous machines using this curve as default. direct
curveStyle cim:Curve.curveStyle No cardinality available CurveStyle The style or shape of the curve. Curve
xUnit cim:Curve.xUnit No cardinality available UnitSymbol The X-axis units of measure. Curve
y1Unit cim:Curve.y1Unit No cardinality available UnitSymbol The Y1-axis units of measure. Curve
y2Unit cim:Curve.y2Unit No cardinality available UnitSymbol The Y2-axis units of measure. Curve
CurveDatas cim:Curve.CurveDatas No cardinality available CurveData The point data values that define this curve. Curve
description cim:IdentifiedObject.description No cardinality available string The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. IdentifiedObject
energyIdentCodeEic eu:IdentifiedObject.energyIdentCodeEic No cardinality available string The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. IdentifiedObject
mRID cim:IdentifiedObject.mRID No cardinality available string Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. IdentifiedObject
name cim:IdentifiedObject.name No cardinality available string The name is any free human readable and possibly non unique text naming the object. IdentifiedObject
shortName eu:IdentifiedObject.shortName No cardinality available string The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. IdentifiedObject

Schema Source

Responsive Footer