Jumper

A short section of conductor with negligible impedance which can be manually removed and replaced if the circuit is de-energized. Note that zero-impedance branches can potentially be modelled by other equipment types.

URI: cim:Jumper
Type: Class

%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
    class Jumper
    click Jumper href "/Models/Profiles/SteadyStateHypothesis/ConcreteClasses/Jumper/"
    style Jumper fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Switch <|-- Jumper : inherits
            click Switch href "/Models/Profiles/SteadyStateHypothesis/ConcreteClasses/Switch/"
            style Switch fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ConductingEquipment <|-- Switch : inherits
            click ConductingEquipment href "/Models/Profiles/SteadyStateHypothesis/ConcreteClasses/ConductingEquipment/"
            style ConductingEquipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Equipment <|-- ConductingEquipment : inherits
            click Equipment href "/Models/Profiles/SteadyStateHypothesis/ConcreteClasses/Equipment/"
            style Equipment fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        PowerSystemResource <|-- Equipment : inherits
            click PowerSystemResource href "/Models/Profiles/SteadyStateHypothesis/ConcreteClasses/PowerSystemResource/"
            style PowerSystemResource fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        IdentifiedObject <|-- PowerSystemResource : inherits
            click IdentifiedObject href "/Models/Profiles/SteadyStateHypothesis/ConcreteClasses/IdentifiedObject/"
            style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white



        Switch : Switch.open
        Switch : Switch.locked
        Equipment : Equipment.inService
        IdentifiedObject : IdentifiedObject.mRID

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
open cim:Switch.open No cardinality available boolean The attribute tells if the switch is considered open when used as input to topology processing. Switch
locked cim:Switch.locked No cardinality available boolean If true, the switch is locked. The resulting switch state is a combination of locked and Switch.open attributes as follows:
  • locked=true and Switch.open=true. The resulting state is open and locked;
  • locked=false and Switch.open=true. The resulting state is open;
  • locked=false and Switch.open=false. The resulting state is closed.

| Switch | | inService | cim:Equipment.inService | No cardinality available boolean | Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model. | Equipment | | mRID | cim:IdentifiedObject.mRID | No cardinality available string | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. | IdentifiedObject |