Skip to content

ACDCTerminal

An electrical connection point (AC or DC) to a piece of conducting equipment. Terminals are connected at physical connection points called connectivity nodes.

*NOTE: this is an abstract class and should not be instantiated directly

URI: cim:ACDCTerminal
Type: Class

%%{init: {'theme':'base','themeVariables': {'lineColor': '#FF0000'}}}%%
classDiagram
    class ACDCTerminal
    click ACDCTerminal href "/Models/Profiles/Operation/AbstractClasses/ACDCTerminal/"
    style ACDCTerminal fill:#102820,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ACDCTerminal <|-- Terminal : inherits

        Terminal
            click Terminal href "/Models/Profiles/Operation/ConcreteClasses/Terminal/"
            style Terminal fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        IdentifiedObject <|-- ACDCTerminal : inherits
            click IdentifiedObject href "/Models/Profiles/Operation/AbstractClasses/IdentifiedObject/"
            style IdentifiedObject fill:#8F9779,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        ACDCTerminal --> Measurement : ACDCTerminal.Measurements

        Measurement
            click Measurement href "/Models/Profiles/Operation/AbstractClasses/Measurement/"
            style Measurement fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white

        Measurement --> ACDCTerminal : Measurement.Terminal

        Measurement
            click Measurement href "/Models/Profiles/Operation/AbstractClasses/Measurement/"
            style Measurement fill:#A52A2A,stroke:#333,stroke-width:2px,rx:10,ry:10,color:white


        ACDCTerminal : ACDCTerminal.Measurements
        IdentifiedObject : IdentifiedObject.description
        IdentifiedObject : IdentifiedObject.mRID
        IdentifiedObject : IdentifiedObject.name

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
Measurements cim:ACDCTerminal.Measurements No cardinality available Measurement Measurements associated with this terminal defining where the measurement is placed in the network topology. It may be used, for instance, to capture the sensor position, such as a voltage transformer (PT) at a busbar or a current transformer (CT) at the bar between a breaker and an isolator. direct
description cim:IdentifiedObject.description No cardinality available string The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. IdentifiedObject
mRID cim:IdentifiedObject.mRID No cardinality available string Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. IdentifiedObject
name cim:IdentifiedObject.name No cardinality available string The name is any free human readable and possibly non unique text naming the object. IdentifiedObject

Schema Source