EquivalentInjection
This class represents equivalent injections (generation or load). Voltage regulation is allowed only at the point of connection.
URI: cim:EquivalentInjection
Type: Class
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- EquivalentEquipment
- EquivalentInjection
- EquivalentEquipment
- ConductingEquipment
- Equipment
- PowerSystemResource
Attributes
| Name | URI | Cardinality and Range | Inheritance | Description |
|---|---|---|---|---|
| r | cim:EquivalentInjection.r | 1..1 Resistance | direct | Positive sequence resistance. Used to represent Extended-Ward (IEC 60909).Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| r0 | cim:EquivalentInjection.r0 | 1..1 Resistance | direct | Zero sequence resistance. Used to represent Extended-Ward (IEC 60909).Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| r2 | cim:EquivalentInjection.r2 | 1..1 Resistance | direct | Negative sequence resistance. Used to represent Extended-Ward (IEC 60909).Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| x | cim:EquivalentInjection.x | 1..1 Reactance | direct | Positive sequence reactance. Used to represent Extended-Ward (IEC 60909).Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| x0 | cim:EquivalentInjection.x0 | 1..1 Reactance | direct | Zero sequence reactance. Used to represent Extended-Ward (IEC 60909).Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| x2 | cim:EquivalentInjection.x2 | 1..1 Reactance | direct | Negative sequence reactance. Used to represent Extended-Ward (IEC 60909).Usage : Extended-Ward is a result of network reduction prior to the data exchange. |
| mRID | cim:IdentifiedObject.mRID | 1..1 string | IdentifiedObject | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
Format Examples
{
"@context": {"rdf": "http://www.w3.org/1999/02/22-rdf-syntax-ns#", "linkml": "https://w3id.org/linkml/", "sh": "http://www.w3.org/ns/shacl#", "skos": "http://www.w3.org/2004/02/skos/core#", "dc": "http://purl.org/dc/elements/1.1/", "profcim": "http://iec.ch/TC57/ns/CIM/prof-cim#", "owl": "http://www.w3.org/2002/07/owl#", "cim": "http://iec.ch/TC57/CIM100#", "cims": "http://iec.ch/TC57/1999/rdf-schema-extensions-19990926#", "this": "http://ucaiug.org/ns/CGMES/ShortCircuit-EU/3.0#", "dct": "http://purl.org/dc/terms/", "rdfs": "http://www.w3.org/2000/01/rdf-schema#", "dcat": "http://www.w3.org/ns/dcat#", "eu": "http://iec.ch/TC57/CIM100-European#"},
"@id": "urn:uuid:<uuid>",
"@type": "cim:EquivalentInjection",
"cim:EquivalentInjection.r": "float",
"cim:EquivalentInjection.r0": "float",
"cim:EquivalentInjection.r2": "float",
"cim:EquivalentInjection.x": "float",
"cim:EquivalentInjection.x0": "float",
"cim:EquivalentInjection.x2": "float",
"cim:IdentifiedObject.mRID": "string"
}
<cim:EquivalentInjection rdf:ID="_<uuid>">
<cim:EquivalentInjection.r>float</cim:EquivalentInjection.r>
<cim:EquivalentInjection.r0>float</cim:EquivalentInjection.r0>
<cim:EquivalentInjection.r2>float</cim:EquivalentInjection.r2>
<cim:EquivalentInjection.x>float</cim:EquivalentInjection.x>
<cim:EquivalentInjection.x0>float</cim:EquivalentInjection.x0>
<cim:EquivalentInjection.x2>float</cim:EquivalentInjection.x2>
<cim:IdentifiedObject.mRID>string</cim:IdentifiedObject.mRID>
</cim:EquivalentInjection>
{
"r": "float",
"r0": "float",
"r2": "float",
"x": "float",
"x0": "float",
"x2": "float",
"mRID": "string"
}
<urn:uuid:<graph-id>> {
<urn:uuid:<uuid>>
a cim:EquivalentInjection ;
cim:EquivalentInjection.r "float" ;
cim:EquivalentInjection.r0 "float" ;
cim:EquivalentInjection.r2 "float" ;
cim:EquivalentInjection.x "float" ;
cim:EquivalentInjection.x0 "float" ;
cim:EquivalentInjection.x2 "float" ;
cim:IdentifiedObject.mRID "string" .
}
Schema Source
- from schema: http://ucaiug.org/ns/CGMES/ShortCircuit-EU/3.0