DCLineSegment
A wire or combination of wires not insulated from one another, with consistent electrical characteristics, used to carry direct current between points in the DC region of the power system.
URI: cim:DCLineSegment
Type: Class
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- DCConductingEquipment
- DCLineSegment
- DCConductingEquipment
- Equipment
- PowerSystemResource
Attributes
| Name | URI | Cardinality and Range | Inheritance | Description |
|---|---|---|---|---|
| capacitance | cim:DCLineSegment.capacitance | 1..1 Capacitance | direct | Capacitance of the DC line segment. Significant for cables only. |
| inductance | cim:DCLineSegment.inductance | 1..1 Inductance | direct | Inductance of the DC line segment. Negligible compared with DCSeriesDevice used for smoothing. |
| length | cim:DCLineSegment.length | 0..1 Length | direct | Segment length for calculating line section capabilities. |
| resistance | cim:DCLineSegment.resistance | 1..1 Resistance | direct | Resistance of the DC line segment. |
| ratedUdc | cim:DCConductingEquipment.ratedUdc | 1..1 Voltage | DCConductingEquipment | Rated DC device voltage. The attribute shall be a positive value. It is configuration data used in power flow. |
| aggregate | cim:Equipment.aggregate | 0..1 boolean | Equipment | The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to “true” the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine.The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection. |
| normallyInService | cim:Equipment.normallyInService | 0..1 boolean | Equipment | Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model. |
| EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer | Equipment | Container of this equipment. |
| mRID | cim:IdentifiedObject.mRID | 1..1 string | IdentifiedObject | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. |
| description | cim:IdentifiedObject.description | 0..1 string | IdentifiedObject | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. |
| energyIdentCodeEic | eu:IdentifiedObject.energyIdentCodeEic | 0..1 string | IdentifiedObject | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. |
| name | cim:IdentifiedObject.name | 1..1 string | IdentifiedObject | The name is any free human readable and possibly non unique text naming the object. |
| shortName | eu:IdentifiedObject.shortName | 0..1 string | IdentifiedObject | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. |
Format Examples
{
"@context": {"rdf": "http://www.w3.org/1999/02/22-rdf-syntax-ns#", "linkml": "https://w3id.org/linkml/", "sh": "http://www.w3.org/ns/shacl#", "skos": "http://www.w3.org/2004/02/skos/core#", "dc": "http://purl.org/dc/elements/1.1/", "profcim": "http://iec.ch/TC57/ns/CIM/prof-cim#", "owl": "http://www.w3.org/2002/07/owl#", "cim": "http://iec.ch/TC57/CIM100#", "this": "http://ucaiug.org/ns/CGMES/CoreEquipment-EU/3.0#", "cims": "http://iec.ch/TC57/1999/rdf-schema-extensions-19990926#", "dct": "http://purl.org/dc/terms/", "rdfs": "http://www.w3.org/2000/01/rdf-schema#", "dcat": "http://www.w3.org/ns/dcat#", "eu": "http://iec.ch/TC57/CIM100-European#"},
"@id": "urn:uuid:<uuid>",
"@type": "cim:DCLineSegment",
"cim:DCLineSegment.capacitance": "float",
"cim:DCLineSegment.inductance": "float",
"cim:DCLineSegment.length": "float",
"cim:DCLineSegment.resistance": "float",
"cim:DCConductingEquipment.ratedUdc": "float",
"cim:Equipment.aggregate": "boolean",
"cim:Equipment.normallyInService": "boolean",
"cim:Equipment.EquipmentContainer": { "@id": "urn:uuid:<uuid of EquipmentContainer>" },
"cim:IdentifiedObject.mRID": "string",
"cim:IdentifiedObject.description": "string",
"eu:IdentifiedObject.energyIdentCodeEic": "string",
"cim:IdentifiedObject.name": "string",
"eu:IdentifiedObject.shortName": "string"
}
<cim:DCLineSegment rdf:ID="_<uuid>">
<cim:DCLineSegment.capacitance>float</cim:DCLineSegment.capacitance>
<cim:DCLineSegment.inductance>float</cim:DCLineSegment.inductance>
<cim:DCLineSegment.length>float</cim:DCLineSegment.length>
<cim:DCLineSegment.resistance>float</cim:DCLineSegment.resistance>
<cim:DCConductingEquipment.ratedUdc>float</cim:DCConductingEquipment.ratedUdc>
<cim:Equipment.aggregate>boolean</cim:Equipment.aggregate>
<cim:Equipment.normallyInService>boolean</cim:Equipment.normallyInService>
<cim:Equipment.EquipmentContainer rdf:resource="#_<uuid of EquipmentContainer>" />
<cim:IdentifiedObject.mRID>string</cim:IdentifiedObject.mRID>
<cim:IdentifiedObject.description>string</cim:IdentifiedObject.description>
<eu:IdentifiedObject.energyIdentCodeEic>string</eu:IdentifiedObject.energyIdentCodeEic>
<cim:IdentifiedObject.name>string</cim:IdentifiedObject.name>
<eu:IdentifiedObject.shortName>string</eu:IdentifiedObject.shortName>
</cim:DCLineSegment>
{
"capacitance": "float",
"inductance": "float",
"length": "float",
"resistance": "float",
"ratedUdc": "float",
"aggregate": "boolean",
"normallyInService": "boolean",
"EquipmentContainer": "<EquipmentContainer>",
"mRID": "string",
"description": "string",
"energyIdentCodeEic": "string",
"name": "string",
"shortName": "string"
}
<urn:uuid:<graph-id>> {
<urn:uuid:<uuid>>
a cim:DCLineSegment ;
cim:DCLineSegment.capacitance "float" ;
cim:DCLineSegment.inductance "float" ;
cim:DCLineSegment.length "float" ;
cim:DCLineSegment.resistance "float" ;
cim:DCConductingEquipment.ratedUdc "float" ;
cim:Equipment.aggregate "boolean" ;
cim:Equipment.normallyInService "boolean" ;
cim:Equipment.EquipmentContainer <urn:uuid:<uuid of EquipmentContainer>> ;
cim:IdentifiedObject.mRID "string" ;
cim:IdentifiedObject.description "string" ;
eu:IdentifiedObject.energyIdentCodeEic "string" ;
cim:IdentifiedObject.name "string" ;
eu:IdentifiedObject.shortName "string" .
}
Schema Source
- from schema: http://ucaiug.org/ns/CGMES/CoreEquipment-EU/3.0